Klinisk & analytiskBB-44613905
Auto ELISA Processor BIOBASE2000
Introduction: The auto elisa processor is an analytical instrument used in the field of hospital, laboratory. Its main function is to analyze sample pre-processing, sample analysis and data processing.
Specifikationer
- ModelBIOBASE2000
- Pipetting10~1000μl
- Dispensing System2 aspirating and dispensing probe( X-Y-Z movement)
- Pipetting Range10~1000μl, 1μl stepping
- Pipetting Precision(100μl)CV≤1.0%
- Washing ProbesTwo line 8-nozzle manifolds
- Wash ContainersCleaning fluid(15L), waste water(25L), Buffer 1(5L), Buffer 2(2L), Buffer 3(2L), Buffer 4(2L), with liquid level-sensing, liquid shortage and full alarm
- Waste Containers25L with waste full sensor
- Washing Residual<2μl
- Absorbance0.0~3.0OD
- Spectral Range400~700nm
- Optical Filters2 standard filters(450, 630nm); 2 more on request (405nm/450nm/492nm/630nm)
- Reading Accuracy±1% from 0~1.5OD, ±2% from 1.5~3.0OD
- Temperature RangeRT to 45℃
- Temperature Accuracy±0.5℃
- LIS SystemBi-direction, support HL7 protocol
- ResultsAbsorbance and results reviewable by software
- PrinterExternal optional
- Temperature10~30℃
- Humidity30%~80%
- Net Weight146kg
- Package Size(W*D*H)1380*860*1415mm
- Gross Weight220kg
Detaljer
Features: 1. 1 robotic arm, 2 pipetting probes(10~1000μl). 2. 4 units 96 well microplates(independent incubating). 3. 1 unit reader&washer(auto reading and washing). Technical Parameters: Model BIOBASE2000 Sample Unit Sample Racks Standard 192 sample positions(expandable, up to 552) Pipetting 10~1000μl Dispensing System 2 aspirating and dispensing probe( X-Y-Z movement) Reagent Unit Reagent Position 23 reagent racks, editable Pipetting Range 10~1000μl, 1μl stepping Pipetting Precision (100μl)CV≤1.0% Washing Unit Dispensing Time 4 minutes to whole 96 to microplates Washing Probes Two line 8-nozzle manifolds Wash Containers Cleaning fluid(15L), waste water(25L), Buffer 1(5L), Buffer 2(2L), Buffer 3(2L), Buffer 4(2L), with liquid level-sensing, liquid shortage and full alarm Waste Containers 25L with waste full sensor Washing Residual <2μl Reading Unit Reading Channels 8 independent photometric channels, mono anddichromatic reading Absorbance 0.0~3.0OD Spectral Range 400~700nm Optical Filters 2 standard filters(450, 630nm); 2 more on request (405nm/450nm/492nm/630nm) Reading Accuracy ±1% from 0~1.5OD, ±2% from 1.5~3.0OD Incubation Unit Incubators 4 independent units Temperature Range RT to 45℃ Temperature Accuracy ±0.5℃ Data Management Software System Above Windows 7 system LIS System Bi-direction, support HL7 protocol Results Absorbance and results reviewable by software Printer External optional Working Conditions Power Supply AC220V±10%, 50/60Hz; 110V±10%, 60Hz, 400W Temperature 10~30℃ Humidity 30%~80% Size&Weight External Size(W*D*H) 1235*705*875mm Net Weight 146kg Package Size(W*D*H) 1380*860*1415mm Gross Weight 220kg




