Auto ELISA Processor BIOBASE1001

Introduction: The Auto ELISA Processor BIOBASE1001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks. , animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.

Pris på forespørgselPris aftales individuelt — kontakt os.

Specifikationer

  • ModelBIOBASE1001
  • Sampling Channel1 channel
  • Liquid Level DetectionAir pressure level detection, clot detection function
  • Tip1000μl, 2 Tip racks
  • Pipetting10μl~1000μl
  • Pipetting Precision100μl: CV≤1%, Accuracy≤2.5% 1000μl: CV≤0.5%, Accuracy≤1%
  • Reagent Position2 Reagent racks
  • Dilution Plate Position1 dilution plate position with incubation and shaking
  • Washing Head16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery
  • Injection UniformityCV<1.5%
  • Washing Residual<2μl
  • Absorbance Range0.000~4.000Abs
  • Linear Range0.000~3.000Abs
  • RepeatabilityCV≤1.0%
  • Stability≤±0.003Abs
  • Spectral Range400~700nm
  • Optical Filters4 standard filters(405, 450, 492, 630nm) Total 10 filters positions
  • Reading Accuracy≤±0.02Abs from 0.0 to 1.0 OD ≤±0.03Abs from 1.0 to 2.0 OD
  • Sensitivity≥0.01mg/L
  • Channel Difference≤0.02Abs
  • Cover Position1(2 covers)
  • Heating MethodDry heating with cover
  • Shaking FunctionHorizontal circular oscillation, 1~3 levels adjustable, amplitude 2.5mm
  • Temperature RangeRT to 60 °C
  • Temperature Uniformity±0.5℃
  • Temperature Fluctuation±0.5℃
  • LIS SystemBi-direction, support HL7 protocol
  • ResultsAbsorbance and results reviewable by software
  • PrinterExternal optional
  • Built-in ScannerOptional
  • DisinfectionUV lamp
  • LightingLED
  • IAP FunctionFirmware can be upgraded online at any time
  • Temperature10~40℃
  • Humidity30~80%
  • Net Weight155kg; 55kg
  • Package Size(W*D*H)1050*850*1150mm 1100*820*750mm
  • Gross Weight210kg; 105kg

Detaljer

&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Features: 1. Adopt the principle of pressure type liquid detection. 2. With TIP detection, clot detection function. 3. High-precision pipetting, the lowest volume can reach 10μl. 4. Position sensing, real-time monitoring of gripper status. 5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates and plate covers of different sizes. 6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other. Technical Parameters: Model BIOBASE1001 Sample&Reagent Unit Sample Racks 6*20 push-pull sample racks Sampling Channel 1 channel Liquid Level Detection Air pressure level detection, clot detection function Tip 1000μl, 2 Tip racks Pipetting 10μl~1000μl Pipetting Precision 100μl: CV≤1%, Accuracy≤2.5% 1000μl: CV≤0.5%, Accuracy≤1% Reagent Position 2 Reagent racks Dilution Plate Position 1 dilution plate position with incubation and shaking Washing Unit Washer 1 unit Washing Head 16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery Injection Uniformity CV<1.5% Washing Residual <2μl Reading Unit Reading Channels 8 independent photometric channels, mono and dichromatic reading Absorbance Range 0.000~4.000Abs Linear Range 0.000~3.000Abs Repeatability CV≤1.0% Stability ≤±0.003Abs Spectral Range 400~700nm Optical Filters 4 standard filters(405, 450, 492, 630nm) Total 10 filters positions Reading Accuracy ≤±0.02Abs from 0.0 to 1.0 OD ≤±0.03Abs from 1.0 to 2.0 OD Sensitivity ≥0.01mg/L Channel Difference ≤0.02Abs Incubation Unit Incubators 2 shaking incubators Cover Position 1(2 covers) Heating Method Dry heating with cover Shaking Function Horizontal circular oscillation, 1~3 levels adjustable, amplitude 2.5mm Temperature Range RT to 60 °C Temperature Uniformity ±0.5℃ Temperature Fluctuation ±0.5℃ Data Management Software Above Windows 7 system LIS System Bi-direction, support HL7 protocol Results Absorbance and results reviewable by software Printer External optional Built-in Scanner Optional Other Function Biosafety Protection Optional(Negative pressure working zone, HEPA filter) Disinfection UV lamp Lighting LED IAP Function Firmware can be upgraded online at any time Working Condition Power Supply AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz(Optional) Temperature 10~40℃ Humidity 30~80% Size&Weight External Size(W*D*H) 870*680*870; 465*475*700mm Net Weight 155kg; 55kg Package Size(W*D*H) 1050*850*1150mm 1100*820*750mm Gross Weight 210kg; 105kg