Laboratory EquipmentBB-105856538
Automatic Uncovering Centrifuge BKC-AU5MT BKC-AU5BT BKC-AU5KT
Introduction: Vacuum-collecting vessels are widely used in hospitals at all levels when collecting blood samples. After blood centrifugation, the cap must be removed manually, which is inefficient. The shaking may cause the blood to remix and increase the risk of infection. In this regard, the automatic hat centrifuge is a set of hat, centrifuge completed at a time, effectively improve the work efficiency, reduce the labor intensity of medical staff; Eliminate the risk of potential biological contamination by manually opening the cover to the medical staff.
Specifications
- Max. Speed5000rpm
- Max. RCF4390×g
- Max. Capacity4*500ml
- Speed Precision±1% or ±20rpm, take the highest value
- Time Range1s~999min
- Noise≤65dB
- Consumption500W
- Power SupplyAC110~220V, 50/60Hz
- External Size(L*W*H)615*450*368mm
- Package Size(L*W*H)780*600*650mm
- Net Weight44kg
- Gross Weight64.5kg
Details
Features: 1. Embedded microprocessor control, high control precision, real-time display speed, time, RCF value. 2. 10 kinds of lifting speed for choice, the lifting speed is fast, the speed can be adjusted within a certain range during operation. 3. Maximum torque motor direct drive, no carbon powder pollution, maintenance-free, long service life. 4. OLED LCD digital display, real-time display of all operating parameters, intuitive and convenient operation. 5. Over-speed, unbalanced protection, safe and reliable; program memory function, automatic memory of the previous operation set parameters, boot automatically restore the parameters set before shutdown. 6. Cap removal rate of 99%, effectively prevent cross infection, blood spatter and broken pipe. Technical Parameters: Model BKC-AU5MT BKC-AU5BT BKC-AU5KT Max. Speed 5000rpm Max. RCF 4390×g Max. Capacity 4*500ml Speed Precision ±1% or ±20rpm, take the highest value Time Range 1s~999min Noise ≤65dB Consumption 500W Power Supply AC110~220V, 50/60Hz External Size(L*W*H) 615*450*368mm Package Size(L*W*H) 780*600*650mm Net Weight 44kg Gross Weight 64.5kg Rotor: NO. Rotors Type Capacity Max. Speed Max. RCF Adapter NO.1 Swing Rotor 4*12*5ml vacuum blood collection tube (for BKC-AU5MT) 4000rpm 3580×g 4*12*2ml NO.2 4*20*5mlvacuum blood collection tube(for BKC-AU5BT) 4000rpm 3580×g 4*20*2ml NO.3 4*24*5ml vacuum blood collection tube (for BKC-AU5KT) 4000rpm 3580×g 4*24*2ml Note: The default is round-bottom tube, with mark (▲) is sharp-bottom tube.